Appl Radiat Isot ; 200: 110945, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37515859

RESUMO

The Bureau International des Poids et Mesures (BIPM) is developing a new transfer instrument to extend its centralized services for assessing the international equivalence of radioactive standards to new radionuclides. A liquid scintillation counter using the triple/double coincidence ratio method is being studied and tested in the CCRI(II)-P1.Co-60 pilot study. The pilot study, involving 13 participating laboratories with primary calibration capabilities, validated the approach against the original international reference system based on ionization chambers, which has been in operation since 1976. The results are in agreement and an accuracy suitable for purpose, below 5×10-4, is achieved. The pilot study also reveals an issue when impurities emitting low-energy electrons are present in the standard solution, which have a different impact on liquid scintillation counting compared to other primary measurement methods.

2.
Appl Radiat Isot ; 116: 157-62, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27544313

RESUMO

The performance of a Cadmiun Telluride (CdTe) detector for low energy photon spectrometry was evaluated. Collected data were analyzed using the basic software package available with the CdTe detector system and the COLEGRAM code developed for photopeak deconvolution at LNHB/France. Several calibrated point sources were used to determine the energy versus efficiency curve. The efficiency curve was used in the determination of main X-ray intensities of (153)Sm and (177)Lu.

3.
Appl Radiat Isot ; 66(6-7): 981-7, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18346902

RESUMO

Proficiency tests were applied to assess the performance of 74 nuclear medicine services in activity measurements of (131)I, (123)I, (99)Tc(m), (67)Ga and (201)Tl. These tests produced 913 data sets from comparison programmes promoted by the National Laboratory for Ionizing Radiation Metrology (LNMRI) from 1999 to 2006. The data were evaluated against acceptance criteria for accuracy and precision and assigned as Acceptable or Not acceptable accordingly. In addition, three other statistical parameters were used as complementary information for performance evaluation which related to normative requirements and to radionuclide calibrators. The results have shown a necessity to improve quality control procedures and unsatisfactory performances of radionuclide calibrators, which incorporate Geiger-Müller detectors.